Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
ABCS health sci ; 45: [1-7], 02 jun 2020. tab
Artigo em Inglês | LILACS | ID: biblio-1097559

RESUMO

INTRODUCTION: Long-term disabilities are frequently related to postoperative complications on breast cancer patients. OBJECTIVE: To assess the effect of breast cancer surgery on pulmonary function and respiratory muscle strength over the course of 60 days after the surgery. METHODS: Prospective study with 32 women. Pulmonary function was evaluated using spirometry and respiratory muscle strength was evaluated using manovacuometry. The evaluations were performed in preoperative period, between 12 to 48h after surgery, 30 and 60 days after the surgery. RESULTS: Vital capacity (VC) and inspiratory capacity (IC) were diminished 48h after surgery (VC: 2.18±0.63; IC: 1.71±0.49; p<0.01 vs baseline), returned to the baseline parameters after 30 days (VC: 2.76±0.60; CI: 2.16±0.57; p<0.01 vs PO48h) and were maintained after 60 days of the surgery (VC: 2.64±0.60; CI: 2.11±0.62; p<0.01 vs PO48h). No difference was observed in tidal volume over the evaluations, except when comparing 60 days to the 48h after surgery values (0.84±0.37 vs 0.64±0.19, respectively; p=0.028). Respiratory muscle strength was reduced 48h after surgery (MIP: -33.89±12.9 cmH2O; MEP: 39.72±21.0 cmH2O; p<0.01 vs basal) and returned to baseline values after 30 (MIP: -50.1±21.2 cmH2O; MEP: 59.86±24.7 cmH2O; p<0.01 vs PO48h) and 60 days of the surgery (MIP: -50.78±19.2 cmH2O; MEP: 61.67±23.4 cmH2O; p<0.01vs PO48h). CONCLUSION: Breast cancer surgery does not impact pulmonary function and respiratory muscle strength 30 days after the surgery.


INTRODUÇÃO: Mulheres com câncer de mama podem apresentar complicações a longo-prazo relacionadas ao procedimento cirúrgico. OBJETIVO: Avaliar a função pulmonar e a força muscular respiratória em mulheres submetidas a tratamento cirúrgico para câncer de mama ao longo de 60 dias. MÉTODOS: Estudo longitudinal com 32 mulheres. A função pulmonar e a força muscular respiratória foram avaliadas utilizando espirometria e manovacuometria, respectivamente, no pré-operatório, de 12 a 48h no período pós-operatório, 30 dias e 60 dias após a cirurgia. RESULTADOS: A capacidade vital (CV) e a capacidade inspiratória (CI) apresentaram redução significante no pós-operatório de até 48h (CV: 2,18±0,63; CI: 1,71±0,49; p<0,01 vs basal), com retorno aos parâmetros basais em 30 dias após a cirurgia (CV: 2,76±0,60; CI: 2,16±0,57; p<0,01 vs PO48h) e manutenção destes no pós-operatório de 60 dias (CV: 2,64±0,60; CI: 2,11±0,62; p< 0,01 vs PO48h). Não foi observada diferença estatisticamente significante entre os valores de volume corrente nos quatro períodos avaliados, exceto quando comparado o período pós-operatório de 60 dias com o pós-operatório de até 48h (0,84±0,37 vs 0,64±0,19, respectivamente; p=0,028). Todos os valores de força muscular respiratória apresentaram-se significantemente reduzidos no pós-operatório de até 48h (PImax: -33,89±12,9 cmH2O; PEmax: 39,72±21,0 cmH2O; p<0,01 vs basal), com retorno aos valores basais em 30 (PImax: -50,1±21,2 cmH2O; PEmax: 59,86±24,7 cmH2O; p<0,01 vs PO48h) e 60 dias (PImax -50,78±19,2 cmH2O; PEmax 61,67±23.4 cmH2O; p<0,01 vs PO48h). CONCLUSÃO: A cirurgia para tratamento do câncer de mama não impacta na função pulmonar e força muscular respiratória 30 dias após a cirurgia.


Assuntos
Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Espirometria , Músculos Respiratórios , Neoplasias da Mama/cirurgia
2.
Rev. Paul. Pediatr. (Ed. Port., Online) ; 36(4): 500-510, out.-dez. 2018. tab, graf
Artigo em Português | LILACS | ID: biblio-977081

RESUMO

RESUMO Objetivos: Identificar estudos que avaliam as propriedades psicométricas dos principais testes de capacidade funcional utilizados em crianças e adolescentes e verificar os testes que apresentam propriedades de mensuração satisfatórias. Fontes de dados: Pesquisa nas bases de dados MEDical Literature Analysis and Retrieval System Online (MEDLINE), Cumulative Index to Nursing and Allied Health Literature (CINAHL) e Scientific Electronic Library Online (SciELO), sem limitar o período ou idiomas. Dois investigadores selecionaram de forma independente os artigos com base nos critérios de inclusão: estudos que avaliaram propriedades psicométricas dos testes de capacidade funcional em crianças e/ou adolescentes saudáveis ou com doenças cardiorrespiratórias. Foram excluídas pesquisas que incluíram indivíduos adultos e/ou participantes com doenças neurológicas e estudos que exclusivamente estabeleceram valores de referência ou equações de predição. Síntese dos dados: Do total de 677 artigos, foram selecionados 11 compatíveis com o tema; destes, 7 avaliaram propriedades psicométricas do teste de caminhada de 6 minutos (TC6), 1 avaliou tanto o TC6 quanto o teste do degrau de 3 minutos (TD3), e 3 avaliaram o teste incremental Shuttle Walk Test (ISWT). As evidências sobre as propriedades de reprodutibilidade e confiabilidade são boas para o TC6 e ISWT e moderadas para o TD3. O ISWT mostra medidas de validade altas para crianças saudáveis e para aquelas com doença respiratória crônica. As medidas de validade do TC6 variam entre as populações estudadas e devem ser consideradas de maneira particular para cada condição de doença. A validade do TD3 ainda deve ser esclarecida na população pediátrica. Conclusões: O TC6 apresenta maior número de investigações sobre suas propriedades, mas sua validade apresenta variabilidade para diferentes populações pediátricas. A capacidade dos testes TC6, ISWT e TD3 de mensurar mudanças clinicamente importantes em crianças e adolescentes com doenças cardiorrespiratórias é desconhecida.


ABSTRACT Objectives: To identify studies that evaluated psychometric properties of functional capacity tests in children and adolescents, and to verify which of these have satisfactory properties of measurement. Data sources: Searches on MEDical Literature Analysis and Retrieval System Online (MEDLINE), Cumulative Index to Nursing and Allied Health Literature (CINAHL) and Scientific Electronic Library Online (SciELO) databases without limiting period or language. Two investigators independently selected articles based on the following inclusion criteria: children and/or adolescent population (healthy or with cardiorespiratory diseases); and assessment of psychometric properties of functional capacity tests. Studies with (I) adult samples, (II) sample with neurological diseases, and (III) on reference values or prediction equations only were excluded. Data synthesis: From the total of 677 articles identified, 11 were selected. These evaluated the psychometric properties of the following tests: 6-minute walk test (6MWT) (n=7); 6MWT and the 3-minute step test (3MST) (n=1); and Incremental Shuttle Walk Test (ISWT) (n=3). Reproducibility and reliability were good for 6MWT and ISWT, and moderate for 3MST. The ISWT showed high validity measures for both healthy children and children with chronic respiratory disease. The validity of 6MWT varied across studies, and should be analyzed according to the health conditions of test takers. The validity of 3MST is unclear, and further studies in pediatric population are required. Conclusions: Most studies investigated 6MWT measurement properties. Validity of 6MWT varied according to different pediatric populations. The use of 6MWT, ISWT and 3MST tests to measure clinically important changes in children and adolescents with cardiorespiratory diseases is still unclear.


Assuntos
Humanos , Criança , Adolescente , Teste de Esforço , Psicometria , Reprodutibilidade dos Testes
3.
J. bras. pneumol ; 44(5): 370-377, Sept.-Oct. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-975935

RESUMO

ABSTRACT Objective: To develop reference equations for the Glittre Activities of Daily Living test (Glittre ADL-test) on the basis of anthropometric and demographic variables in apparently healthy individuals. A secondary objective was to determine the reliability of the equations in a sample of COPD patients. Methods: This was a cross-sectional study including 190 apparently healthy individuals (95 males; median age, 54.5 years [range, 42-65]; median FEV1 = 97% [range, 91-105.2]; and median FVC = 96% [range, 88.5-102]) recruited from the general community and 74 COPD patients (55 males; mean age, 65 ± 8 years; body mass index [BMI] = 25.9 ± 4.7 kg/m2; FEV1 = 36.1 ± 14.1%; and FVC = 62.7 ± 16.1%) recruited from a pulmonary rehabilitation center. Results: The mean time to complete the Glittre ADL-test was 2.84 ± 0.45 min. In the stepwise multiple linear regression analysis, age and height were selected as Glittre ADL-test performance predictors, explaining 32.1% (p < 0.01) of the total variance. Equation 1 was as follows: Glittre ADL-testpredicted = 3.049 + (0.015 × ageyears) + (−0.006 × heightcm). Equation 2 included age and BMI and explained 32.3% of the variance in the test, the equation being as follows: Glittre ADL-testpredicted = 1.558 + (0.018 × BMI) + (0.016 × ageyears). Conclusions: The reference equations for the time to complete the Glittre ADL-test were based on age, BMI, and height as independent variables and can be useful for predicting the performance of adult individuals. The predicted values appear to be reliable when applied to COPD patients.


RESUMO Objetivo: Elaborar equações de referência para o teste Glittre Activities of Daily Living (Glittre ADL) com base em variáveis antropométricas e demográficas em indivíduos aparentemente saudáveis. O objetivo secundário foi determinar a confiabilidade das equações em uma amostra composta por pacientes com DPOC. Métodos: Estudo transversal com 190 indivíduos aparentemente saudáveis [95 homens; mediana de idade: 54,5 anos (variação: 42-65); mediana de VEF1 = 97% (variação: 91-105,2); mediana de CVF = 96% (variação: 88,5-102)] recrutados na comunidade geral e 74 pacientes com DPOC [55 homens; média de idade: 65 ± 8 anos; índice de massa corporal (IMC) = 25,9 ± 4,7 kg/m2; VEF1 = 36,1 ± 14,1%; CVF = 62,7 ± 16,1%] recrutados em um centro de reabilitação pulmonar. Resultados: A média do tempo necessário para completar o teste Glittre ADL foi de 2,84 ± 0,45 min. Na análise de regressão linear múltipla passo a passo (stepwise), a idade e a estatura foram selecionadas como preditores do desempenho no teste Glittre ADL, explicando 32,1% (p < 0,01) da variância total. A equação 1 foi a seguinte: Glittre ADLprevisto = 3,049 + (0,015 × idadeanos) + (−0,006 × alturacm). A equação 2 incluiu idade e IMC e explicou 32,3% da variância do teste: Glittre ADLprevisto = 1,558 + (0,018 × IMC) + (0,016 × idadeanos). Conclusões: As equações de referência para o tempo necessário para completar o teste Glittre ADL basearam-se na idade, IMC e estatura como variáveis independentes e podem ser úteis para prever o desempenho de indivíduos adultos. Os valores previstos são aparentemente confiáveis quando aplicados em pacientes com DPOC.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Qualidade de Vida , Atividades Cotidianas , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Teste de Esforço , Padrões de Referência , Estudos Transversais , Reprodutibilidade dos Testes
4.
J. bras. pneumol ; 44(4): 315-320, July-Aug. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-975918

RESUMO

ABSTRACT Objective: To investigate the validity of an eight-contact electrode bioelectrical impedance analysis (BIA) system within a household scale for assessing whole body composition in COPD patients. Methods: Seventeen patients with COPD (mean age = 67 ± 8 years; mean FEV1 = 38.6 ± 16.1% of predicted; and mean body mass index = 24.7 ± 5.4 kg/m2) underwent dual-energy X-ray absorptiometry (DEXA) and an eight-contact electrode BIA system for body composition assessment. Results: There was a strong inter-method correlation for fat mass (r = 0.95), fat-free mass (r = 0.93), and lean mass (r = 0.93), but the correlation was moderate for bone mineral content (r = 0.73; p < 0.01 for all). In the agreement analysis, the values between DEXA and the BIA system differed by only 0.15 kg (−6.39 to 6.70 kg), 0.26 kg (−5.96 to 6.49 kg), −0.13 kg (−0.76 to 0.50 kg), and −0.55 kg (−6.71 to 5.61 kg) for fat-free mass, lean mass, bone mineral content, and fat mass, respectively. Conclusions: The eight-contact electrode BIA system showed to be a valid tool in the assessment of whole body composition in our sample of patients with COPD.


RESUMO Objetivo: Este estudo teve como objetivo investigar a validade de um sistema de bioelectrical impedance analysis (BIA, análise de impedância bioelétrica) com oito eletrodos de contato presente em uma balança doméstica para a avaliação da composição corporal total de pacientes com DPOC. Métodos: Dezessete pacientes com DPOC (média de idade = 67 ± 8 anos; média do VEF1 = 38,6 ± 16,1% do previsto; média de índice de massa corpórea = 24,7 ± 5,4 kg/m2) foram submetidos à avaliação da composição corporal por dual-energy X-ray absorptiometry (DEXA, absorciometria por dupla emissão de raios X) e por um sistema BIA com oito eletrodos de contato. Resultados: Houve forte correlação intermétodos para massa gorda (r = 0,95), massa livre de gordura (r = 0,93) e massa magra (r = 0,93), mas correlação moderada para conteúdo mineral ósseo (r = 0,73; p < 0,01 para todos). Na análise de concordância, os valores entre DEXA e o sistema BIA diferiram em apenas 0,15 kg (−6,39 a 6,70 kg), 0,26 kg (−5,96 a 6,49 kg), −0,13 kg (−0,76 a 0,50 kg) e −0,55 kg (−6,71 a 5,61 kg) para massa livre de gordura, massa magra, conteúdo mineral ósseo e massa gorda, respectivamente. Conclusões: O sistema BIA com oito eletrodos de contato mostrou-se uma ferramenta válida na avaliação da composição corporal total em nossa amostra de pacientes com DPOC.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Composição Corporal/fisiologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Espirometria , Índice de Gravidade de Doença , Absorciometria de Fóton , Estado Nutricional , Estudos Transversais , Reprodutibilidade dos Testes , Impedância Elétrica
5.
J. bras. pneumol ; 44(4): 285-291, July-Aug. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-975927

RESUMO

ABSTRACT Objective: To translate the Understanding COPD (UCOPD) questionnaire into Portuguese, adapt it for use in Brazil, and assess its reliability. Methods: The UCOPD questionnaire consists of two sections, designated section A and section B. Section A comprises 18 items divided into three domains: "About COPD", "Managing Symptoms of COPD", and "Accessing Help and Support". Section B includes five questions regarding patient satisfaction with the educational component of pulmonary rehabilitation programs. The UCOPD questionnaire was applied twice on the same day by two different raters (with a 10-min interval between applications) and once again 15-20 days later. The Wilcoxon test was used in order to compare the scores among applications. Reliability was assessed by the intraclass correlation coefficient and Bland-Altman plots. Results: The study sample consisted of 50 COPD patients (35 men; mean age, 65.3 ± 7.91 years; mean FEV1, 36.4 ± 16.2% of the predicted value). Inter-rater intraclass correlation coefficients for section A total scores and domain scores ranged from moderate to high. Section A scores and domain scores had no significant differences regarding test-retest reliability (p < 0.05). The test-retest and inter-rater Cronbach's alpha coefficients for section A total scores were 0.93 and 0.86, respectively (p < 0.001). There were no floor or ceiling effects. Conclusions: The Brazilian Portuguese version of the UCOPD questionnaire is reliable.


RESUMO Objetivo: Traduzir o questionário Understanding COPD (UCOPD) para o português, adaptá-lo para uso no Brasil e avaliar sua confiabilidade. Métodos: O questionário UCOPD é dividido em duas seções, denominadas seção A e seção B. A seção A compreende 18 itens, divididos em três domínios: "Sobre a DPOC", "Manejo dos Sintomas da DPOC" e "Acesso a Ajuda e Suporte". A seção B inclui cinco itens referentes à satisfação do paciente com o componente educacional dos programas de reabilitação pulmonar. O questionário UCOPD foi aplicado duas vezes no mesmo dia por dois observadores diferentes (com 10 min de intervalo entre uma aplicação e outra) e mais uma vez 15-20 dias depois. O teste de Wilcoxon foi usado para comparar a pontuação obtida em cada aplicação. A confiabilidade foi avaliada por meio do coeficiente de correlação intraclasse e de gráficos de dispersão de Bland-Altman. Resultados: A amostra foi composta por 50 pacientes com DPOC (35 homens; média de idade = 65,3 ± 7,91 anos; média do VEF1 = 36,4 ± 16,2% do valor predito). Os coeficientes de correlação intraclasse referentes à análise interobservador da pontuação total da seção A e seus domínios variaram de moderados a elevados. A pontuação obtida na seção A e em seus domínios não apresentou diferenças significativas quanto à confiabilidade teste-reteste (p < 0,05). Os coeficientes alfa de Cronbach de teste-reteste e interobservador referentes à pontuação total da seção A foram de 0,93 e 0,86, respectivamente (p < 0,001). Não foram observados efeitos de piso ou teto. Conclusões: A versão em português do Brasil do questionário UCOPD é confiável.


Assuntos
Humanos , Masculino , Feminino , Idoso , Traduções , Comparação Transcultural , Inquéritos e Questionários , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Brasil , Reprodutibilidade dos Testes
6.
Rev. Nutr. (Online) ; 29(5): 635-644, Sept.-Oct. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-830648

RESUMO

ABSTRACT Objective: To investigate whether there is a relationship between nutritional status and limitations in activities of daily living in patients with chronic obstructive pulmonary disease. Methods: A cross sectional study was conducted from July to December 2011 in Santa Catarina. Seventeen chronic obstructive pulmonary disease patients [age (years) = 67±8; forced expiratory volume in one second (% of the predicted value) = 38.6±16.1; body mass index (kg/m2) = 24.7±5.4] underwent the assessments: pulmonary function (spirometry); functional status (London Chest Activity of Daily Living scale, physical activities in daily life, and Glittre ADL-Test; nutritional status (anthropometry and dual-energy X-Ray absorptiometry). Results: The total score of the London Chest Activity of Daily Living scale correlated with fat-free mass (r=-0.50; p=0.04) and lean mass (r=-0.50; p=0.04). The lying time in physical activities in daily life correlated with bone mineral content (r=-0.50; p=0.04). Nutricional status was not correlated with time spent on Glittre ADL-test. Conclusion: Variables that reflect muscle mass depletion are related to variables of self-reported limitation in activities of daily living. Bone mineral content is correlated with time patients spend lying, reflecting the impact of inactive postures on the nutritional status of these patients.


RESUMO Objetivo: Investigar se existe relação entre o estado nutricional e a limitação em atividades de vida diária em pacientes com doença pulmonar obstrutiva crônica. Métodos: Um estudo transversal foi conduzido de julho a dezembro de 2011 em Santa Catarina. Dezessete pacientes com doença pulmonar obstrutiva crônica [idade (anos) = 67±8; volume expiratório forçado no primeiro segundo (% do valor predito) =38,6±16,1; índice de massa corporal (kg/m2) =24,7±5,4] foram submetidos à avaliação da função pulmonar (espirometria); do estado funcional (escala London Chest Activity of Daily Living, monitorização das atividades físicas na vida diária e teste de AVD-Glittre); e do estado nutricional (antropometria e absorciometria por dupla emissão de Raios X). Resultados: O escore total da escala London Chest Activity of Daily Living correlacionou-se negativamente com a massa livre de gordura (r=-0,50; p=0,04) e com a massa magra (r=-0,50; p=0,04). O tempo deitado nas atividades físicas na vida diária apresentou correlação negativa com o conteúdo mineral ósseo (r=-0,50; p=0,04). Não foram encontradas correlações significativas entre variáveis de estado nutricional e tempo despendido no TGlittre. Conclusão: Variáveis que refletem a depleção muscular estão relacionadas a variáveis de autorrelato de limitação em atividades de vida diária. O conteúdo mineral ósseo correlaciona-se ao tempo que os pacientes permanecem deitados, refletindo o impacto de posturas inativas no estado nutricional desses indivíduos.


Assuntos
Humanos , Masculino , Feminino , Doença Pulmonar Obstrutiva Crônica/complicações , Espirometria , Atividades Cotidianas , Estado Nutricional
7.
Conscientiae saúde (Impr.) ; 15(2): 249-257, 30 jun. 2016.
Artigo em Inglês | LILACS | ID: biblio-846482

RESUMO

Background: Spirometry is the gold-standard diagnosis test for COPD. However, the impulse oscillometry system (IOS) has proven to be effective for early detection of COPD and little is known about the association between the two techniques in the presence or absence of pulmonary disease. Objective: To investigate the association between lung function and lung mechanics using the IOS in patients with COPD and healthy subjects. Methodology: Eighteen patients with COPD and 18 healthy individuals performed spirometry and the IOS. Results: FEV1 and FEF25-75% correlated with X5Hz (r=0.74; r=0.63), and with R5Hz-R20Hz (r=-0.67; r=- 0.51), and FVC moderately correlated with most of the oscillometric parameters (R5Hz, Z5Hz, R5Hz ­ R20Hz, X5Hz and Fres) in the COPD group. Conclusions: Reactance is related to pulmonary airflow obstruction and peripheral resistance is associated with mean forced expiratory flow. Thus, IOS is a method that can complement spirometric findings in patients with COPD.


Introdução: A espirometria é o padrão ouro para diagnosticar a DPOC. Contudo, o sistema de oscilometria de impulso (IOS) tem se mostrado eficaz no diagnóstico precoce da doença e pouco se sabe sobre a associação entre as técnicas na presença e na ausência de doença. Objetivo: Investigar a associação entre função e mecânica pulmonar utilizando o IOS em indivíduos saudáveis e com DPOC. Métodos: Dezoito indivíduos com DPOC e 18 saudáveis realizaram espirometria e IOS. Resultados: O VEF1 e FEF25-75% correlacionaram com X5Hz (r=0,74, r=0,63) e com R5Hz-R20Hz (r=-0.67, r=-0,51); a CVF correlacionou moderadamente com a maioria das variáveis oscilométricas (R5Hz, Z5Hz, R5Hz­R20Hz, X5Hz e Fres) no grupo com DPOC. Conclusões: A reatância está relacionada com a obstrução ao fluxo aéreo pulmonar e a resistência periférica está associada com o fluxo expiratório forçado médio. Portanto, o IOS é um método que pode complementar os achados espirométricos em pacientes com DPOC.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Oscilometria , Mecânica Respiratória , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Testes de Função Respiratória , Pneumologia , Estudos Transversais
8.
J. bras. pneumol ; 42(1): 15-21, Jan.-Feb. 2016. tab, graf
Artigo em Português | LILACS | ID: lil-776480

RESUMO

Objective : To translate The Manchester Respiratory Activities of Daily Living (MRADL) questionnaire into Portuguese and to create a version of the MRADL that is cross-culturally adapted for use in Brazil. Methods : The English-language version of the MRADL was translated into Portuguese by two health care researchers who were fluent in English. A consensus version was obtained by other two researchers and a pulmonologist. That version was back-translated into English by another translator who was a native speaker of English and fluent in Portuguese. The cognitive debriefing process consisted in having 10 COPD patients complete the translated questionnaire in order to test its understandability, clarity, and acceptability in the target population. On the basis of the results, the final Portuguese-language version of the MRADL was produced and approved by the committee and one of the authors of the original questionnaire. Results : The author of the MRADL questioned only a few items in the translated version, and some changes were made to the mobility and personal hygiene domains. Cultural differences regarding the domestic activities domain were found, in particular regarding the item "Do you have the ability to do a full clothes wash and hang them out to dry?", due to socioeconomic and climatic issues. The item "Do you take care of your garden?" was questioned by the participants who lived in apartments, being modified to "Do you take care of your garden or plants in your apartment?" Conclusions : The final Portuguese-language version of the MRADL adapted for use in Brazil was found to be easy to understand and easily applied.


Objetivo : Traduzir para a língua portuguesa e fazer a adaptação cultural do questionário The Manchester Respiratory Activities of Daily Living (MRADL) para uso no Brasil. Métodos : A versão em língua inglesa do MRADL foi traduzida por duas pesquisadoras da área da saúde com fluência na língua inglesa. Uma versão de consenso foi obtida por outras duas pesquisadoras e uma médica pneumologista. Essa versão foi retrotraduzida para o inglês por um tradutor nascido em um país de língua inglesa e fluente em português. O processo de desdobramento cognitivo consistiu em testar a compreensão, a clareza e a aceitabilidade do questionário traduzido na população alvo, aplicando-o em dez indivíduos com DPOC. Com base nos resultados, foi realizada a formulação da versão brasileira do MRADL após sua aprovação pelo comitê e um dos autores do questionário original. Resultados : Poucos itens foram questionados pelo autor da escala original, e algumas modificações relacionadas aos domínios mobilidade e higiene pessoal foram realizadas. Foram observadas diferenças culturais quanto ao domínio atividades domésticas, em especial o item "Consegue lavar a roupa e estendê-la para secar?" devido a condições socioeconômicas e climáticas. O item "cuida do seu jardim?" foi questionado pelos participantes que moravam em apartamentos, sendo modificado para "cuida do seu jardim ou plantas em seu apartamento?". Conclusões : A versão final do MRADL, traduzido e adaptado para uso no Brasil, mostrou ser de fácil compreensão e aplicação.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Atividades Cotidianas , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Respiração , Inquéritos e Questionários/normas , Brasil , Comparação Transcultural , Avaliação da Deficiência , Idioma , Qualidade de Vida , Reprodutibilidade dos Testes , Espirometria , Traduções
9.
Fisioter. pesqui ; 22(2): 104-111, Apr.-June 2015. tab, ilus
Artigo em Português | LILACS | ID: lil-758059

RESUMO

O objetivo deste estudo foi verificar se há correlação entre a capacidade funcional e a percepção da limitação em atividades de vida diária (AVDs) de pacientes com doença pulmonar obstrutiva crônica (DPOC). Trinta pacientes com DPOC foram submetidos a: avaliação antropométrica, espirometria, escala London Chest Activity of Daily Living (LCADL), teste de caminhada de seis minutos (TC6min) e teste de AVD-Glittre (TGlittre). A normalidade dos dados foi testada por meio do teste de Shapiro-Wilk. Para verificar a existência de correlação entre as variáveis, utilizou-se o coeficiente de correlação de Spearman. Uma regressão linear simples e uma regressão linear múltipla stepwise foram aplicadas utilizando-se o percentual da escala LCADL (LCADL%total) como variável dependente e os testes (TGlittre e TC6min) como independentes. O TGlittre correlacionou-se moderadamente com o LCADL%total (r=0,58; p<0,05), o domínio "cuidados pessoais" (r=0,45; p<0,05) e o domínio "lazer" (r=0,54; p<0,05) da escala LCADL. O LCADL%total e o domínio "lazer" apresentaram moderada e fraca correlação negativa com o TC6min (r=0,45 e r=-0,53; p<0,05, respectivamente), enquanto o domínio "cuidados pessoais" não se correlacionou com o mesmo. A variabilidade do TGlittre foi capaz de explicar 44% (p<0,01) da variabilidade do LCADL%total,enquanto do TC6min apenas 20% (p<0,05). No modelo de regressão linear múltipla, apenas o TGlittre foi selecionado como preditor do LCADL%total (R²=0,44; p<0,01). Portanto, o TGlittre e o TC6min refletem as limitações nas AVD percebidas e relatadas por pacientes com DPOC. Entretanto, o TGlittre parece ser mais sensível para refletir a percepção do comprometimento funcional dos pacientes.


Este estudio tiene el propósito de comprobar si hay correlación entre la capacidad funcional y las limitaciones percibidas por pacientes con enfermedad pulmonar obstructiva crónica (EPOC) en las actividades de la vida diaria (AVDs). Se aplicaron a los treinta participantes la evaluación antropométrica, la espirometría, la escala London Chest Activity of Daily Living (LCADL), el test de marcha de 6 minutos (TM6m) y el test de AVD-Glittre (TGlittre). La normalidad de los datos se puso a prueba mediante el test de Shapiro-Wilk, y para comprobar la correlación entre las variables se utilizó el coeficiente de correlación de Spearman. Una regresión lineal simple y una múltiple stepwise se aplicaron mediante el porcentaje de la escala LCADL (LCADL%total) como variable dependiente y las pruebas (TGlittre y TM6m) como independientes. El TGlittre correlacionó moderadamente con la LCADL%total (r=0,58; p<0,05), con el dominio "cuidados personales" (r=0,45; p<0,05) y con el dominio "tiempo de ocio" (r=0,54; p<0,05) de la escala LCADL. La LCADL%total y el dominio "tiempo de ocio" mostraron correlación negativa moderada y débil con el TM6m (r=-0,45 y r=-0,53; p<0,05, respectivamente), mientras que este no correlacionó con el dominio "cuidados personales". Un 44% (p<0,01) de la variación de la LCADL%total se explicó por la variación del TGlittre, mientras que la del TM6m fue solamente un 20% (p<0,05). En el modelo de regresión lineal múltiple se seleccionó solamente el TGlittre como predictor de la LCADL%total (R²=0,44; p<0,01). Se concluyó que tanto el TGlittre como el TM6m mostraron las AVDs percibidas y relatadas por los pacientes con EPOC. Sin embargo, el TGlittre parece ser lo más sensible para percibir la alteración funcional de los pacientes.


The aim of this study was to investigate whether there is a correlation between functional capacity and the perception of limitation for activities of daily living (ADL) in patients with chronic obstructive pulmonary disease (COPD). Thirty patients underwent anthropometric assessment, spirometry, the London Chest Activity of Daily Living Scale (LCADL), the six minute walk test (6mWT) and the Glittre-ALD test (TGlittre). The normality of the data was tested using the Shapiro-Wilk test. To verify correlation between variables, the Spearman correlation coefficient was used. A simple linear regression and stepwise multiple linear regression were applied, using the percentage of LCADL (LCADL%total) as dependent variable and the tests (TGlittre and 6mWT) as independents. The TGlittre correlated moderately with LCADL%total (r=0.58, p<0.05) and with the LCADL domain "self care" (r=0.45, p<0.05) and "leisure" (r=0.54, p<0.05). The LCADL%total and its domain "leisure" showed moderate and weak negative correlation with the 6mWT (r=-0.45 and r=-0.53, p<0.05, respectively), while the "self care" domain did not correlate with 6mWT. The variability of the TGlittre was able to explain 44% of the variability of the LCADL%total (p<0.01), while 6mWT explained only 17% of the LCADL%total (p<0.05). In the multiple linear regression model, only the TGlittre was selected as LCADL%total predictor (R²=0.44; p<0.01). Therefore, both the 6MWT and TGlittre reflect ADL limitations perceived and reported by patients with COPD. However, TGlittre seems to be more sensitive to reflect the self-perception of functional impairment in those patients.

10.
Fisioter. pesqui ; 22(1): 41-47, Jan-Mar/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-744397

RESUMO

The Glittre ADL-test (TGlittre), validated to assess the functional capacity of patients with chronic obstructive pulmonary disease, has as outcome the shortest total time required to complete it. To date, little is known about the time that healthy individuals take to perform it. This study aimed to describe the total and shortest times spent to perform TGlittre in a sample of healthy adults, and to assess the reliability of the test in this population. The subjects underwent spirometry pre- and post-bronchodilator, anthropometric assessment, International Physical Activity Questionnaire and two TGlittre. 35 subjects were evaluated (15 men), of 29±6 years of age, with forced vital capacity (FVC) of 96±10.6% and forced expiratory volume in the first second (FEV1) of 97.6±9.26%, in % of predicted, and FEV1/FVC of 0.86±0.05; height of 1.72±0.11m; weight of 24.5±3.62kg and body mass index of 24.2±3.87kg/m2, being 74.3% and 25.7% with low and moderate physical activity level, respectively. The mean time spent on the test with better performance was 2.62±0.34min. There was no difference in performance among age groups (p>0.05). There was a mean reduction of 6.3±5.8% in the time between TGlittre1 and TGlittre2, however, this difference was not statistically significant (p>0.05). An intraclass correlation coefficient of 0.88 (p<0.05) between the time of TGlittre1 and 2 was found. The results suggest that in a sample of healthy adults, the shortest and mean time to complete the test are 2.03 and 2.62min, respectively, and that TGlittre is reliable in these subjects.


O teste de AVD-Glittre (TGlittre), validado para avaliar a capacidade funcional de indivíduos com doença pulmonar obstrutiva crônica, possui como desfecho o menor tempo despendido para completá-lo. Até o presente momento, pouco se sabe acerca desse tempo no desempenho de indivíduos saudáveis. O objetivo do estudo foi avaliar o tempo total de realização do TGlittre em uma amostra de indivíduos adultos saudáveis, o tempo mínimo de execução do teste, assim como a reprodutibilidade do teste nessa população. Os sujeitos foram submetidos à espirometria pré e pós-broncodilatador, avaliação antropométrica, Questionário Internacional de Atividade Física e dois TGlittre. Foram avaliados 35 indivíduos (15 homens) de 29±6 anos, com capacidade vital forçada (CVF) de 96±10,6%, volume expiratório forçado no primeiro segundo (VEF1) de 97,6±9,26%, em % do previsto, e VEF1/CVF de 0,86±0,05; altura de 1,72±0,11m; peso de 72,3±12,8kg e índice de massa corpórea de 24,5±3,62kg/ m2, sendo que 74,3% e 25,7% tinham níveis baixo e moderado de atividade física, respectivamente. A média de tempo despendido no teste com melhor desempenho foi de 2,62±0,34min. Não se encontrou diferença na execução entre as faixas etárias (p>0,05). Houve redução, em média, de 6,3±5,8% no tempo entre o TGlittre1 e TGlittre2, porém essa diferença não foi estatisticamente significante (p>0,05). Encontrou-se um coeficiente de correlação intraclasse de 0,88 (p<0,05) entre os tempos do TGlittre1 e TGlittre2. Os resultados demonstraram que, em uma amostra de adultos jovens saudáveis, o tempo mínimo e a média para completar o teste são de 2,62min e 2,03min, respectivamente, e que este é reprodutível nesses indivíduos.


La prueba AVD-Glittre (PGlittre), validada para evaluar la capacidad funcional de sujetos con enfermedad pulmonar obstructiva crónica, tiene como resultado el menor tiempo dedicado para completarla. Hasta el presente, poco se conoce sobre este tiempo en el rendimiento de sujetos sanos. Para eso, el objectivo fue evaluar el tiempo total de realización de la PGlittre en una muestra de sujetos adultos sanos, el tiempo mínimo de ejecución de la prueba, así como su reproductibilidad en la población. Los sujetos se sometieron a la espirometría pre y pos broncodilatador, a la evaluación antropométrica, al Cuestionario Internacional de Actividad Física y a dos PGlittre. Se han evaluados 35 sujetos (15 varones) de 29±6 años, con capacidad vital forzada (CVF) de 96±10,6%, volumen espiratorio forzado en el primer segundo (VEF1) de 97,6±9,26%, en % del previsto, y VEF1/ CVF de 0,86±0,05; altura de 1,72±0,11m; peso de 72,3±12,8kg e índice de masa corporal de 24,5±3,62kg/m2, en el que el 74,3% y 25,7% tenían bajo y moderado nivel de actividad física, respectivos. La media de tiempo en la prueba con mejor rendimiento fue de 2,62±0,34min. No se ha encontrado diferencias en la ejecución entre el rango de edad (p>0,05). Ha ocurrido una reducción, en media, de 6,3±5,8% en el tiempo entre la PGlittre1 y PGlittre2, pero esa diferencia no ha sido significante estadisticamente (p>0,05). Se ha encontrado un coeficiente de correlación interclase de 0,88 (p<0,05) entre los tiempos de la PGlittre1 y PGlittre2. Los resultados mostraron que, en una muestra de adultos jóvenes sanos, el tiempo mínimo y la media para completar la prueba fueron de 2,62min y 2,03min, respectivamente, y que esto es reproductible en estos sujetos.


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Idoso , Atividades Cotidianas , Tolerância ao Exercício , Reprodutibilidade dos Testes , Espirometria/métodos , Doença Pulmonar Obstrutiva Crônica , Inquéritos e Questionários
11.
Rev. bras. ciênc. mov ; 23(1): 136-145, jan.-mar.2015. tab, graf
Artigo em Português | LILACS | ID: lil-758695

RESUMO

A redução de força muscular está presente em pacientes com insuficiência cardíaca (IC),normalmente associada a perda de massa muscular, gerando fadiga e dispneia, que pode reduzir a capacidade de executar as atividades de vida diária (AVD). Entretanto, o impacto do prejuízo da força de cada compartimento muscular – de membros superiores, inferiores e respiratório - na capacidade funcional de pacientes com IC permanece desconhecido. Portanto, o presente estudo teve como objetivo verificar a relação das forças musculares respiratória e periférica com a capacidade funcional em pacientes com IC. Nove sujeitos com IC, idade de 53,5±6 anos, classe funcional II e III (NYHA) e fração de ejeção de ventrículo esquerdo (FEVE) de 26,2±8,1% foram avaliados quanto a: função pulmonar, pressão muscular inspiratória (PImax) e expiratória (PEmax), força muscular de quadríceps (FMq) e de preensão palmar(FMp), tempo despendido no teste de AVD-Glittre (TGlittre), distância percorrida no teste da caminhada de seis minutos (TC6min) e escores de dispneia e limitação funcional. A FMq foi 29,7±6,3 kgf;71±18,8%prev, FMp foi 355,5±87,9 N; 96,1±16,2%prev. A PImax foi de -69,4±26,2 cmH2O;64,4±22,2% prev e a PEmax foi de 94,1±16,3 cmH2O; 78,4±26%prev. O tempo médio despendido noTGlittre foi 4,9±1,3min e a distância no TC6min foi 417,6±97,1m, que correspondeu a 74,4±18,3%prev. OTG littre mostrou forte correlação com a FMq (r=-0,82; p=0,006), não apresentando associação com as demais forças musculares. O domínio atividades domésticas da LCADL se correlacionou com distância doTC6min (r=-0,79; p=0,01). A FMp apresentou correlação significante com a PImax (r=0,76; p=0,01) e com a FMq (r=0,70; p=0,03). Conclui-se que os pacientes com IC estudados apresentam redução de força muscular inspiratória, expiratória e de membros inferiores. Entretanto, somente a força de membros inferiores mostrou estar fortemente relacionada à limitação funcional nesses pacientes...


The reduction of muscle strength is present in patients with heart failure (HF), usuallyassociated with loss of muscle mass, causing fatigue and dyspnea, which may reduce the ability to performactivities of daily living (ADL). However, the impact of the loss of strength of each muscle compartment –respiratory, upper and lower limbs - in the functional capacity of patients with HF remains unknown.Therefore, this study aimed to examine the relation between respiratory and peripheral muscle strengthwith functional capacity in patients with HF. Nine subjects with HF, age 53.5 ± 6 years, NYHA functionalclass II and III and left ventricle ejection fraction (LVEF) of 26.2 ± 8.1% were evaluated for pulmonaryfunction, maximal inspiratory (MIP) and expiratory (MEP) pressure, quadriceps (QMS) and hand grip(HGS) strength, time spent in the ADL-Glittre test (TGlittre), distance covered on the six-minute walk test(6MWT) and dyspnea and functional limitation scores. The QMS was 29,7±6,3 kgf; 71±18,8% pred, HGSwas 355,5±87,9 N; 96,1±16,2% pred. The MIP was -69,4±26,2 cmH2O; 64,4±22,2%pred and the MEP was94,1±16,3 cmH2O; 78,4±26%pred. Mean time spent on TGlittre was 4,9±1,3min and the distance coveredon 6MWT was 417,6±97,1m, corresponding to 74,4±18,3%pred. The TGlittre strongly correlated withQMS (r=-0.82; p=0.006), with no significant association with other muscle forces. The domestic activitiesdomain of LCADL correlated with 6MWT distance (r=-0.79; p=0.01). The HGS showed significantcorrelation with MIP (r=0.76; p=0.01) and with the QMS (r=0.70; p=0.03). We conclude that HF patientsstudied have reduced inspiratory, expiratory and lower limbs muscle strength. However, only the lowerlimb strength was shown to be strongly related to functional limitation in these patients...


Assuntos
Humanos , Masculino , Feminino , Adulto , Insuficiência Cardíaca , Força Muscular , Educação Física e Treinamento
12.
Artigo em Português | LILACS | ID: lil-743704

RESUMO

Objetivos: Realizar uma revisão não sistemática da literatura a fim de explorar os principais instrumentos utilizados para avaliar a limitação funcional de pacientes com DPOC. Métodos: Pesquisou-se nas bases de dados Medline, PubMed e SciELO, usando-se os termos: atividades de vida diária, atividades cotidianas, atividades físicas na vida diária, capacidade funcional e doença pulmonar obstrutiva crônica. Resultados: Os principais instrumentos foram classificados, conforme suas características, em: questionários e escalas, testes clínicos e sensores de movimento. Descreveram-se a escala LCADL e o questionário PFSDQ. Quanto aos testes clínicos são apresentados: TC6min, AVD-Glittre (TGlittre), Sentar e Levantar, Step Chester e GST, além dos sensores de movimento. Conclusões: Na seleção dos instrumentos de avaliação ideais, devem-se considerar ferramentas que possibilitem atingir os aspectos importantes relacionados à doença e ao impacto que esta causa nesses indivíduos. Dentre os instrumentos apresentados, destacam-se LCADL, TC6min, TGlittre e acelerômetros triaxiais.


Objectives: To perform a non-systematic literature review in order to explore the main instruments used to assess functional limitation in patients with COPD. Methods: The search was performed in Medline, PubMed and SciELO using the following terms: daily activities, physical activities in daily life, functional capacity and chronic obstructive pulmonary disease. Results: The main instruments were classified according to their characteristics: scales and questionnaires, clinical tests and motion sensors. The LCADL scale and the PFSDQ questionnaire were described. Regarding clinical tests there are presented 6MWT, Glittre-ADL Test (TGlittre), Sit to Stand, Step Chester and GST test; besides the motion sensors. Conclusions: In the selection of ideal assessment tools, we must take into account those that tackle important issues related to the disease and to the impact that it has on these patients. Among the tools presented it is highlighted the use of LCADL, 6MWT, TGlittre and triaxial accelerometers.


Assuntos
Humanos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Desempenho Físico Funcional , Pesos e Medidas/instrumentação , Inquéritos e Questionários/classificação
13.
Fisioter. mov ; 27(3): 361-369, 09/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-725450

RESUMO

Introduction Functional status is an important component of health related quality of life (QOL) in patients with chronic obstructive pulmonary disease (COPD). However there is a lack of studies aiming to evaluate the association between QOL and the different methods for assessing patient´s limitation to perform ADL. Objectives To investigate the association between QOL and functional status, measured by four different instruments: London Chest Activity of Daily Living scale (LCADL), six-minute walking test (6MWT), Glittre ADL-test (TGlittre) and assessment of physical activities in daily living (PADL). Methods Twenty-three patients with COPD, GOLD 2 to 4, were submitted to the following evaluations: spirometry, the Saint George Respiratory Questionnaire (SGRQ), LCADL, 6MWT, TGlittre and assessment of PADL. Pearson or Spearman correlation coefficients were used to verify the association between the variables. Results It was observed correlation between all domains of the SGRQ and the 6MWT, between TGlittre and ‘leisure’ domain of LCADL; and between the domain ‘activity’ of the SGRQ with the total score of LCADL (r = 0.53), LCADL% (r = 0.54), ‘self care’ (r = 0.49) and ‘leisure’ (r = 0.82). The number of steps correlated with the SGRQ (r = -0.59) and with ‘activity’ (r = -0.70) and ‘impact’ (r = -0.52) domains. The standing time correlated with the domain ‘activitiy’ (r = -0.47) of the SGRQ (p < 0.05 for all). Conclusions Both functional performance and capacity are able to reflect the impact that ADL limitation has on QOL in patients with COPD .


Introdução O estado funcional é um componente importante da qualidade de vida (QV) relacionada à saúde em pacientes com doença pulmonar obstrutiva crônica (DPOC). Entretanto há uma escassez de estudos associando a QV com os diversos métodos de avaliação das limitações em atividades de vida diária (AVD). Objetivos Verificar se existe associação entre QV e estado funcional, mensurado por diferentes métodos: escala London Chest Activity of Daily Living (LCADL), Teste de Caminhada de Seis Minutos (TC6min), Teste de AVD-Glittre (TGlittre) e monitorização das atividades físicas de vida diária (AFVD). Métodos 23 pacientes com DPOC, GOLD 2 a 4, submetidos às avaliações: espirometria, questionário de QV, Questionário Saint George na Doença Respiratória (SGRQ), escala LCADL, TC6min, TGlittre e monitorização das AFVD. Coeficientes de correlação de Pearson ou Spearman foram utilizados para verificar associação entre as variáveis. Resultados Verificou-se correlação entre todos os domínios do SGRQ e o TC6min, entre o TGlittre e domínio ‘lazer’ da escala LCADL; entre o domínio ‘atividades’ do SGRQ e o escore total da escala LCADL (r = 0,53), LCADL %total (r = 0,54) e com seus domínios ‘cuidados pessoais’ (r=0,49) e ‘lazer’ (0,82). O número de passos se correlacionou com SGRQ (r = -0,59), com ‘atividades’ (r = -0,70) e ‘impacto’ (r = -0,52); o tempo em pé correlacionou-se com o domínio ‘atividades’ (r = -0,47) do SGRQ (p < 0,05 para todas as correlações). Conclusões em pacientes com DPOC, tanto a capacidade quanto a performance funcional são capazes de refletir o impacto que a limitação de AVD exerce ...

14.
Fisioter. pesqui ; 21(3): 279-284, Jul-Sep/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-728756

RESUMO

Was verified the reproducibility of the six-minute walk test (6MWT) in Brazilian healthy children. A transversal cross-sectional observational study was carried out between October 2012 and July 2013, with healthy children aged between 6 and 14 years. Initially, the participants were assessed as biometric data (weight, height, body mass index, body surface area and length of the lower limbs) and spirometry. Two 6MWT were performed with 30min interval between them. The retest was carried out after two weeks. Statistical analysis included Shapiro-Wilk normality and analysis of variance (ANOVA) tests for comparison between the 6MWT; intraclass correlation coefficient - two way mixed model, consistency (ICC) were used to assess reproducibility, as well as the provision Bland & Altman. The level of significance was 5% (p<0,05). Were enrolled 29 children in the study (16 females, mean age 10,28±2,25 years). Reproducibility was found between the two longest 6MWT distances, with ICC=0,82 (p<0,001) as well as similarity in behavior of physiological parameters. The children walked similar distances in the first and second test on both days, showing a walking distance variation (Δ) both negative on day 1 and on day 2 (-5,52 m [confidence interval of 95% (95%CI) -28,475-17,417 m] and -2,26 m [95%CI -28,503-23,982 m], respectively). The 6MWT showed to be reproducible in healthy schoolchildren. The retest showed no improvement in the performance of the studied population, suggesting no learning effect.


Se verificó la reproducibilidad del test de caminata de seis minutos(TC6min) en niños brasileños saludables. Este estudio transversal observacional se llevó a cabo entre octubre de 2012 y julio de 2013 con niños sanos de edades comprendidas entre 6 y 14 años. Inicialmente, los estudiantes fueron evaluados en cuanto a sus datos biométricos (peso, altura, índice de masa corporal - IMC, área de superficie corporal y longitud de miembros inferiores) y espirométricos. En seguida, fueron realizados 2 TC6min con un intervalo de 30 minutos entre ellos. El reteste se llevó a cabo tras dos semanas. El análisis estadístico incluyó pruebas de normalidad Shapiro-Wilk y análisis de la varianza (ANOVA), para la comparación entre los TC6min; el coeficiente de correlación intraclase de dos vías (consistencia) (ICC) se utilizó para verificar la reproducibilidad, así como la disposición gráfica de Bland y Altman. El nivel de significación adoptado fue de 5% (p<0,05). Participaran del estudio 29 estudiantes, siendo 16 del sexo femenino, con edad mediana de 10,28±2,25 años. Analizándose los TC6min con mayor distancia recorrida (DR), se identificó la reproducibilidad del test, con ICC=0,82 (p<0,001), así como la similitud en el comportamiento de los parámetros fisiológicos considerados. Los niños caminaron distancias similares en el primer y en el segundo teste en ambos días, presentando una variación (∆) negativa de la DR tanto el día 1 como el día 2 (-5,52 m [intervalo de confianza de 95% (IC95%) -28,475-17,417 m] y -2,26 m [IC95% -28,503-23,982 m], respectivamente). El TC6min se mostró reproducible en estudiantes sanos. La repetición del test no presentó ninguna mejora en el rendimiento, sugiriendo no haber efecto de aprendizaje en la población estudiada.


Verificou-se a reprodutibilidade do teste de caminhada de seis minutos (TC6min) em crianças saudáveis brasileiras. Este estudo observacional transversal foi realizado entre outubro de 2012 e julho de 2013 com crianças saudáveis com idades entre 6 e 14 anos. Inicialmente, os escolares foram avaliados quanto aos dados biométricos (peso, altura, índice de massa corporal - IMC, área de superfície corporal e comprimento dos membros inferiores) e espirométricos. Na sequência, foram realizados 2 TC6min, com intervalo de 30 minutos entre eles. O reteste foi conduzido após duas semanas. A análise estatística incluiu os testes de normalidade Shapiro-Wilk e análise de variância (ANOVA), para comparação entre os TC6min; o coeficiente de correlação intraclasse de duas vias (consistência) (ICC) foi utilizado na verificação da reprodutibilidade, bem como a disposição gráfica de Bland e Altman. O nível de significância adotado foi de 5% (p<0,05). Participaram do estudo 29 escolares, sendo 16 do sexo feminino, com média de idade de 10,28±2,25 anos. Analisando-se os TC6min com maior distância percorrida (DP), identificou-se reprodutibilidade do teste, com ICC=0,82 (p<0,001), assim como semelhança no comportamento dos parâmetros fisiológicos considerados. As crianças caminharam distâncias similares no primeiro e segundo teste em ambos os dias, apresentando uma variação (∆) negativa da DP tanto no dia 1 como no dia 2 (-5,52 m [intervalo de confiança de 95% (IC95%) -28,475-17,417 m] e -2,26 m [IC95% -28,503-23,982 m], respectivamente). O TC6min mostrou-se reprodutível em escolares saudáveis. A repetição do teste não apresentou melhora no desempenho, sugerindo não haver efeito aprendizado na população estudada.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Caminhada/normas , Exercício Físico , Reprodutibilidade dos Testes , Brasil , Estudos Transversais
15.
ABCS health sci ; 39(1): 56-60, jan.-abr. 2014. graf, tab
Artigo em Português | LILACS | ID: lil-746739

RESUMO

INTRODUÇÃO: A doença pulmonar obstrutiva crônica (DPOC) prejudica o estado funcional, com consequente limitação das atividades de vida diária (AVD). Este estudo teve como objetivo investigar o efeito de um programa de reabilitação pulmonar (RP), em longo prazo, no estado funcional, na dispneia e no índice BODE em pacientes com DPOC. RELATO DE CASO: Trata-se de um estudo retrospectivo e documental, com análise dos prontuários de cinco pacientes participantes de um programa de RP por um ano. Destes prontuários foram coletados dados referentes às avaliações: espirometria, índice de massa corporal (IMC), escalas London Chest Activity of Daily Living (LCADL) e Medical Research Council (MRC) e teste de caminhada de seis minutos (TC6min). Após um ano participando do programa de exercício físico, a maioria dos pacientes apresentou maior capacidade funcional, menor dispneia e redução no risco de mortalidade. CONCLUSÃO: Um ano de RP parece ter função de manutenção da melhora da capacidade funcional de pacientes com DPOC obtida após 24 sessões de treinamento.


INTRODUCTION: The chronic obstructive pulmonary disease (COPD) impairs the functional status with consequent impairment of the activities of daily living (ADL). This study aimed to investigate the effect of a long term pulmonary rehabilitation (PR) on the functional status, dyspnea and on the BODE index in patients with COPD. CASE REPORT: This is a retrospective and descriptive study. The records of five patients that participated in a year PRprogram were analyzed. Assessments about spirometry, body mass index (BMI), London Chest Activity of Daily Living (LCADL) and Medical Research Council (MRC) scales and six-minute walking test (6MWT) were collected. After a year participating in the PR program, most patients improved their functional capacity, dyspnea and reduced the risk of mortality. CONCLUSION: A year of PR seemed to maintain the improvement in functional capacityobtained after 24 training sessions in patients with COPD.


Assuntos
Humanos , Atividades Cotidianas , Doença Pulmonar Obstrutiva Crônica , Exercício Físico , Mortalidade , Reabilitação , Tolerância ao Exercício
16.
Rev. bras. med. esporte ; 17(5): 310-314, set.-out. 2011. ilus, tab
Artigo em Português | LILACS | ID: lil-611394

RESUMO

A limitação nas atividades de vida diária (AVD) por dispneia é um achado comum nos pacientes com insuficiência cardíaca (IC), classe funcional III e IV. A avaliação específica da limitação nas AVD poderia ser utilizada como parâmetro de evolução da doença e de resposta terapêutica. Entretanto, há uma escassez de instrumentos de avaliação das AVD nessa população. Dessa forma, o objetivo do estudo foi verificar a aplicabilidade da escala London Chest Activity of Daily Living (LCADL) e do teste de AVD-Glittre (T Glittre), na avaliação da limitação funcional de indivíduos com IC classe funcional III e IV. Participaram do estudo 10 pacientes (57 ± 9 anos; 27,5 ± 4,5kg/m²) de ambos os sexos com diagnóstico clínico de IC classe funcional III e IV e fração de ejeção do ventrículo esquerdo (FEVE) 34 ± 7 por cento, foram avaliados: espirometria, índice de massa corpórea (IMC), escala LCADL, teste de caminhada de seis minutos (TC6min), T Glittre, escala Medical Research Council (MRC) e questionário SF-36. Os pacientes apresentaram, em média, escore da escala LCADLtotal de 27,7 ± 12,1 (LCADL por centototal: 41,5 ± 16,9) e tempo do T Glittre de 6,3 ± 4,8 minutos, encontrando-se correlação positiva entre eles (r = 0,88; p < 0,05). O LCADL por centototal correlacionou-se com o TC6min (r = -0,83), FEVE (r = -0,64), MRC (r = 0,68) e domínio capacidade funcional (CF) do SF-36 (r = -0,63), com p < 0,05. O T Glittre correlacionou-se com o TC6min (r = -0,90), FEVE (r = -0,66) e CF do SF-36 (r = -0,69), com p < 0,05. Conclui-se com o estudo que a escala LCADL e o T Glittre têm aplicabilidade em pacientes com IC classe III e IV, apresentando associação com a FEVE, com a distância percorrida no TC6min, grau de dispneia e qualidade de vida.


Limitation in activities of daily living (ADL) caused by dyspnea is a common finding in patients with heart failure (HF), functional class III and IV. Specific assessment of ADL limitation could be used as a parameter of the disease progression and the therapy response. However, there is a shortage of instruments to assess ADL in this population. This study aimed to determine the applicability of the London Chest Activity of Daily Living (LCADL) and the Glittre ADL-test (T Glittre), to evaluate functional limitations of individuals with HF functional class III and IV. Ten patients (57±9 years, 27.5±4.5kg/m²) of both genders with a clinical diagnosis of HF functional class III and IV and left ventricle ejection fraction (LVEF) 34±7 percent participated in the study. Spirometry, body mass index (BMI), LCADL, six-minute walking test (6MWT), T Glittre, Medical Research Council Scale (MRC) and SF-36 were performed. The patients had an average score of the LCADLtotal from 27.7±12.1 (LCADL percenttotal: 41.5±16.9) and time of T Glittre 6.3±4.8 minutes. A positive correlation was found between them (r = 0.88, p<0.05). LCADL percenttotal correlated with 6MWT (r =-0.83), LVEF (r =-0.64), MRC (r =0.68) and Functional Capacity (FC) of the SF-36 (r =-0.63) (p<0.05). T Glittre correlated with 6MWT (r =-0.90), LVEF (r =-0.66) and CF of the SF-36 (r =-0.69) (p<0.05). In conclusion, the LCADL scale and T Glittre have applicability in patients with HF class III and IV, demonstrating association with LVEF, distance on the 6MWT, degree of dyspnea and quality of life.


Assuntos
Humanos , Masculino , Feminino , Adulto , Atividades Cotidianas , Dispneia , Insuficiência Cardíaca , Pesos e Medidas
17.
Arq. ciências saúde UNIPAR ; 14(3)set.-dez. 2010. tab
Artigo em Português | LILACS | ID: lil-621330

RESUMO

O objetivo do estudo foi investigar a força muscular periférica e respiratória e a capacidade de execução das atividades de vida diária, em pacientes com Doença Pulmonar Obstrutiva Crônica (DPOC). Trata-se de um relatos de caso composto por cinco pacientes submetidos a avaliação espirométrica e antropométrica, pico de torque isométrico de quadríceps, força de preensão palmar e as pressões respiratórias máximas. Foram aplicados: teste de AVD-Glittre, escalas London Chest Activity Daily Living (LCADL) e Medical Research Council (MRC), e questionários de qualidade de vida SF-36 e o Saint George na Doença Respiratória (SGRQ). Dos cinco pacientes avaliados (quatro do gênero masculino), dois tinham DPOC moderada, dois grave e um muito grave. As idades variaram de 57 a 67 anos. A pressão inspiratória máxima variou de 66% a 205% do valor previsto, enquanto a pressão expiratória máxima oscilou entre 95% e 131%. O percentual previsto da força de preensão palmar permaneceu entre 87% e 107%. Já o pico de torque isométrico de quadríceps variou de 38% a 86% do valor previsto. O teste de AVD-Glittre foi executado entre 3,13min e 6,46min. Os resultados encontrados sugerem uma associação entre forças musculares periférica e respiratória e a limitação nas AVD, porém mais estudos com delineamento adequado para testar essas associações deverão ser realizados.


The study aimed to investigate the respiratory and peripheral muscle strength and the capacity to perform activities of daily living in patients with Chronic Obstructive Pulmonary Disease COPD. In this reported case five patients were submitted to the following measurements: spirometry, anthropometry, isometric quadriceps peak torque, handgrip strength, maximal respiratory pressures, activities of daily living levels (ADL-Glittre), levels of dyspnea (London Chest Activity Daily Living; Medical Research Council) and quality of life (SF-36; Saint George Respiratory Questionnaire - SGRQ). Two patients had moderate COPD, two had severe COPD and one had very severe COPD. All five patients (1 female) were between 57 and 67 years old. The maximal inspiratory pressure varied from 66% to 205% predicted while the maximal expiratory pressure varied from 95% to 131% predicted. The handgrip strength varied from 87% to 107% predicted. The isometric quadriceps peak torque varied from 38% to 86% predicted. The ADL-Glittre was performed between 3.13min and 6.46min. The findings suggest that there is a positive association between the respiratory and peripheral muscle strength and the performance in ADL, however further studies, appropriately designed to investigate such association will take place.


Assuntos
Humanos , Masculino , Feminino , Atividades Cotidianas , Doença Pulmonar Obstrutiva Crônica
18.
Rev. saúde pública ; 42(4): 672-678, ago. 2008. tab
Artigo em Português | LILACS | ID: lil-488987

RESUMO

OBJETIVO: Avaliar o nível de atividade física em estudantes universitários e sua associação com hábito de fumar. MÉTODOS: Estudo transversal com amostragem estratificada proporcional por conglomerados realizado em Gurupi, TO, em 2005. A amostra estudada incluiu 871 universitários. Para avaliar o nível de atividade física foi aplicado o questionário International Physical Activity Questionnaire-8. O consumo tabagístico foi avaliado por questionário modificado da Organização Mundial de Saúde e o grau de dependência nicotínica dos fumantes pela escala de Fagerstrõm. As freqüências, prevalências e razões de prevalência de tabagismo e sedentarismo foram determinadas aplicando-se o teste qui-quadrado pelo método de Yates ou o teste exato de Fisher, segundo grupo geral e estratificadas por área, curso, turno e sexo, ao nível de significância de 5 por cento. RESULTADOS: A média de idade foi 25 (dp±8) anos e a média da idade da primeira experiência tabagística foi 17 (dp±4) anos. A prevalência de sedentarismo foi de 29,9 por cento e de tabagismo 7,2 por cento. A prevalência geral de sedentários fumantes foi de 8,5 por cento e a de não-fumantes 91,5 por cento; mas sem diferença na proporção de sedentários entre fumantes e não-fumantes. Tabagismo e sedentarismo foram mais prevalentes em indivíduos acima de 25 anos (48,6 por cento, p<0,05). O grau de dependência nicotínica muito baixo foi o mais prevalente (68,2 por cento, p<0,05). O consumo tabagístico foi mais prevalente no sexo masculino (10,8 por cento, p<0,05) e a prevalência de sedentarismo não foi diferente entre os sexos (p>0,05). CONCLUSÕES: Sedentarismo ocorreu em fumantes e não-fumantes na mesma proporção, não indicando associação entre esses dois fatores. As baixas prevalências de sedentarismo e tabagismo encontradas podem estar associadas à atuação de programas nacionais, pela aplicação de medidas preventivas e educativas contínuas, sendo necessário que sejam mantidos em longo prazo.


OBJECTIVE: To evaluate the level of physical activity in undergraduate students and to investigate its potential association with smoking. METHODS: A cross-sectional study with a stratified sample proportional to the total number of students was carried out in Gurupi, Central-West Brazil, in 2005. The sample comprised 871 subjects. The IPAQ-8 short version was applied to assess the level of physical activity. Smoking status was evaluated by a modified World Health Organization (WHO) questionnaire and the magnitude of smokers' nicotine dependence was quantified using the Fagerstrõm nicotine dependence scale. The frequencies, prevalences and prevalence ratios were determined by Yates' chi-square test or Fisher's exact test in the entire sample and stratified by area, course, shift and gender, with a 5 percent statistical significance level. RESULTS: Mean age was 25 years old (SD±8) and mean age at first smoking experience was 17 years old (SD±4). The prevalence of physical inactivity and smoking was 29.9 percent and 7.2 percent, respectively. The overall prevalence of sedentary smokers and non-smokers was 8.5 percent, and 91.5 percent, respectively, but the difference was not statistically significant. A higher prevalence of smoking and physical inactivity was found in those over 25 (48.6 percent, p <0.05). Nicotine dependence was "very low" in most subjects (68.2 percent, p <0.05). Smoking was more prevalent in males (10.8 percent, p <0.05) and the level of physical inactivity was not different in both males and females (p >0.05). CONCLUSIONS: Physical inactivity was seen on both smokers and non-smokers in the same proportion and no association was found between these two variables. Low prevalences of physical inactivity and smoking found in the study may be explained by available ongoing preventive and education programs, which should be implemented in the long run.


OBJETIVO: Evaluar el nivel de actividad física en estudiantes universitarios y su asociación con el hábito de fumar. MÉTODOS: Estudio transversal con muestra estratificada proporcional por conglomerados realizado en Gurupi (Norte de Brasil), en 2005. La muestra estudiada incluye 871 universitarios. Para evaluar el nivel de actividad física fue aplicado el cuestionario International Physical Activity Questionnaire-8. El consumo de tabaco fue evaluado por cuestionario modificado de la Organización Mundial de Salud y el grado de dependencia nicotínica de los fumantes por la escala de Fagerstrõm. Las frecuencias, prevalencias y razones de prevalencia de tabaquismo y sedentarismo fueron determinadas aplicando el teste ji-cuadrado pelo método de Yates o el test exacto de Fisher, según grupo general y estratificadas por área, curso, turno y sexo, al nivel de significancia de 5 por ciento. RESULTADOS: La media de edad fue 25 (dp±8) años y la media de edad de la primera experiencia tabaquistica fue 17 (dp±4) años. La prevalencia de sedentarismo fue de 29,9 por ciento y de tabaquismo 7,2 por ciento. La prevalencia general de sedentarios fumantes fue de 8,5 por ciento y la de no-fumantes 91,5 por ciento; pero sin diferencia en la proporción de sedentarios entre fumantes y no-fumantes. Tabaquismo y sedentarismo fueron más prevalentes en individuos arriba de 25 años (48,6 por ciento, p<0,05).El grado de dependencia nicotínica muy bajo fue el más prevalente (68,2 por ciento, p<0,05). El consumo de tabaco fue más prevalente en el sexo masculino (10,8 por ciento, p<0,05) y la prevalencia de sedentarismo no fue diferente entre los sexos (p>0,05). CONCLUSIONES: Sedentarismo ocurre en fumantes y no-fumantes en la misma proporción, no indicando asociación entre esos dos factores. Las bajas prevalencias de sedentarismo y tabaquismo encontradas pueden estar asociadas a la actuación de programas nacionales, por la aplicación de medidas preventivas y educativas...


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Conhecimentos, Atitudes e Prática em Saúde , Atividade Motora/fisiologia , Fumar/epidemiologia , Estudantes de Ciências da Saúde/estatística & dados numéricos , Brasil/epidemiologia , Distribuição de Qui-Quadrado , Estudos Transversais , Atividades de Lazer , Inquéritos e Questionários , Adulto Jovem
19.
J. bras. pneumol ; 34(3): 143-151, mar. 2008. ilus, tab
Artigo em Inglês, Português | LILACS | ID: lil-479631

RESUMO

OBJETIVO: Traduzir a escala London Chest Activity of Daily Living (LCADL) para o português e verificar se essa versão é reprodutível em pacientes com doença pulmonar obstrutiva crônica (DPOC) grave no Brasil. MÉTODOS: Foram realizadas a tradução da escala LCADL para o português e a tradução retrógrada dessa versão em português para o inglês. Essa primeira versão em português foi aplicada a 8 pacientes com DPOC, e possíveis dificuldades em relação ao texto foram investigadas. As principais dificuldades encontradas foram discutidas com os autores da escala, chegando-se a uma versão final do instrumento. Essa versão final foi aplicada duas vezes a 31 pacientes com DPOC por dois observadores separadamente em um primeiro dia. Após 15-20 dias, essa mesma versão foi aplicada novamente aos mesmos pacientes por um dos observadores. No primeiro dia os pacientes foram submetidos à prova de função pulmonar e ao teste de caminhada de seis minutos (TC6). RESULTADOS: A versão brasileira da escala LCADL demonstrou excelente reprodutibilidade no escore total e na maioria das questões, com um coeficiente alfa de Cronbach interobservador de 0,97 (IC95 por cento: 0,89-0,97; p < 0,05) e um coeficiente alfa de Cronbach intra-observador de 0,96 (IC95 por cento: 0,83-0,96; p < 0,05). O escore total dessa versão apresentou correlação negativa com o volume expiratório forçado no primeiro segundo em litros (r = -0,49; p < 0,05) e a distância percorrida no TC6 (r = -0,56; p < 0,05). CONCLUSÃO: A versão brasileira da escala LCADL é um instrumento confiável, reprodutível e válido para avaliar a dispnéia durante atividades de vida diária em pacientes com DPOC grave.


OBJECTIVE: To translate the London Chest Activity of Daily Living (LCADL) scale into Portuguese and to determine whether this version is reproducible in Brazilian patients with severe chronic obstructive pulmonary disease (COPD). METHODS: The LCADL scale was translated into Portuguese and then back-translated into English. This pilot Brazilian Portuguese version was administered to 8 patients with COPD, and possible text-related problems were investigated. The principal problems were discussed with the authors of the original scale, and a final translated version was arrived at. At the study outset, two observers administered this final version (twice in one day) to 31 patients with COPD. One of those observers again administered the scale to the same patients 15-20 days later. At baseline, the patients were submitted to pulmonary function testing and to the six-minute walk test (6MWT). RESULTS: The Brazilian Portuguese version of the LCADL scale demonstrated excellent reproducibility in the total score and in most of the questions, with an inter-rater Cronbach's alpha coefficient of 0.97 (95 percent CI: 0.89-0.97; p < 0.01) and an intra-rater Cronbach's alpha coefficient of 0.96 (95 percent CI: 0.83-0.96; p < 0.01). The total score presented a negative correlation with forced expiratory volume in one second in liters (r = -0.49; p < 0.05) and with distance covered on the 6MWT (r = -0.56; p < 0.05). CONCLUSION: The Brazilian Portuguese version of the LCADL scale is a reliable, reproducible, and valid instrument for evaluating dyspnea during activities of daily living in patients with severe COPD.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Atividades Cotidianas , Dispneia/diagnóstico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Inquéritos e Questionários/normas , Brasil , Teste de Esforço , Tolerância ao Exercício/fisiologia , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Testes de Função Respiratória , Sensibilidade e Especificidade , Espirometria , Traduções
20.
São Paulo; s.n; 2004. [112] p.
Tese em Português | LILACS | ID: lil-419262

RESUMO

Introdução: A deterioração muscular periférica é uma condição progressiva da DPOC e diversos fatores estão relacionados ao seu aparecimento e gravidade, entretanto o tabagismo nunca havia sido estudado como potencial fator. Objetivos: Investigar se a exposição aguda (2 horas) e sub-aguda (5 dias e 25 dias) à fumaça de cigarro causa aumento na permeabilidade do sarcolema elou na proporção e morfometria das fibras dos músculos diaphragma e vasto lateral de ratos; validar um modelo de exposição à fumaça de cigarro. Material e Métodos: O modelo de exposição ao cigarro é constituído de uma câmara de acrílico com capacidade para expor oito ratos simultaneamente; 21 ratos foram expostos uma única vez por duas horas e sacrificados imediatamente (0 h; n = 4), após duas (2 h; n = 4), quatro (4 h; n = 4), 24 (24 h; n = 4) e 48 horas (48 h; n = 5) da exposição. Quatro ratos serviram de controle. A câmara recebia a fumaça de cigarro (50-100ml/min) e ar comprimido (5L/min) para manter uma concentração de monóxido de carbono entre 45-55 ppm no seu interior. Analisou-se a carboxihemoglobina (HbCO) e a cotinina sérica dos animais. Os efeitos do cigarro nos músculos diaphragma e vasto lateral foram avaliados em 48 ratos, em modelos de exposição de duas horas (E2h; n=16), de cinco dias (E5d; n=8) e de 25 dias (E25d; n=8). Cada grupo tinha o seu respectivo grupo controle (C2h, C5d e C25d), composto de quatro ratos cada. Após 24 horas do término das exposições os ratos foram sacrificados e seus músculos retirados para análise. Permeabilidade do sarcolema foi avaliado com o anticorpo anti-albumina, considerado lesão quando eram de grau 2 e 3. Proporção e morfometria de fibras foram analisados com anti-corpos monoclonais para miosina I e II. Resultados: No modelo de validação do método, houve aumento da HbCO imediatamente após a exposição (3 por cento) comparado ao controle (0 por cento) e da cotinina nos tempos 0 h, 2 h e 4 h após a exposição (17 ± 4, 12 ± 9 e 13 ± 6, respectivamente, vs. 0 ng/ml no grupo controle). No diaphragma e no vasto lateral as médias fibras com lesões de sarcolema foram 41,3 ± 19,2 e 18,8 ± 13,6 (E2h), 51,9 ± 26,5 e 17,8 ± 15,0 por cento (E5d), 33,3 ± 23,3 e 10,0 ± 10,5 por cento (E25d), respectivamente, comparado a 17,9 ± 15,5 e 4,1 ± 4,7 por cento no grupo controle..


Assuntos
Músculo Esquelético , Ratos , Músculos Respiratórios , Sarcolema , Tabagismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA